nVent Nuheat Logo, nuheat.com
Schluter-Systems-logo.jpg
SunTouch logo.jpg

Cable & Membrane Comparison

 
Home, nuheat.com
 
nuheat membrane.png
schluter cable.jpg
schluter membrane.jpg
Warmwire.jpg
suntouch membrane.jpg


Indoor Use Only

YES

NO, need approval for outdoor

YES


Online Estimator Tool

NO


120V Sizes - designed at approx. 12 w/sqft

8, 12, 15, 25, 30, 40, 50, 60, 70, 80, 85, 95, 110, 120 (sqft)

11, 16, 21, 27, 32, 38, 43, 51, 64, 73, 83, 92, 102, 113, 134 (sqft)

10, 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 (sqft)


240V Sizes - designed at approx. 12 w/sqft

15, 20, 25, 35, 45, 55, 65, 70, 85, 90, 100, 120, 135, 145, 160, 170, 190, 215, 240 (sqft)

11, 16, 21, 27, 32, 38, 43, 53, 64, 75, 85, 103, 129, 145, 167, 183, 204, 225 (sqft)

20, 30, 40, 50, 60, 70, 80, 90, 100, 120, 140, 160, 180, 200 (sqft)


Max Heat Output

15 watts/sqft

15.2 watts/sqft

14.4 watts/sqft


Cable Spacing w/guides

Unknown

12 w/sqft - 3”

15 w/sqft - 3”/2”/3” alternate

N/A

N/A

N/A

10.3 w/sqft - 3.5”

12 w/sqft - 3”

14.3 w/sqft - 2.5”


Cable Spacing w/membrane

10 w/sqft - 3 pillar

12 w/sqft - 3/2/3 alternate pillar

15 w/sqft - 2 pillar

Unknown

12.7 w/sqft - 3 pillar

15.2 w/sqft - 3/2/3 alternate pillar

10.6 w/sqft - 3/4/3 alternate shape

12.3 w/sqft - 3 shape

14.3 w/sqft - 3/2/3 alternate shape


Cable Guides/Straps Included

YES

NO

YES


Self-Leveling Concrete Using Cable Guides

Recommended

N/A

Recommended, or thicker mortar bed


Cable Thickness

3/16”

Unknown

Unknown


Zero EMF

YES

stated as “virtually zero EMF”

< 1 milligauss


Waterproof Cable

YES

No, extra waterproofing layer required

YES


Halfway Marker on Cable

YES

NO

NO


Cable Repair Kit Available

YES

YES

YES


Cable Must be Turned After 10’

No; Unlimited Straight Runs

YES

No; Unlimited Straight Runs


Cold Lead Length

10’

7’

10’


Cable Splice and Sensor Probe Fits without Cutting Membrane

YES

NO

NO


Membrane Rolls Sizes

54 sqft & 161 sqft

134.5 sqft

40 sqft & 161 sqft


Membrane Sheet Sizes

10.6 sqft - 3’3”x3’3”

8.4 sqft - 3’ 2-5/8” x 2’ 7-3/8”

10 sqft - 3.13’ L x 3.28’ W


Membrane Thickness

.22” - 5.5mm

.25” - 5.5mm

.24” - 6mm


Adjusted Floor Height

Cable w/guides - 1/4”

Cable w/membrane - 1/2”

N/A

Cable w/membrane - 1/2”

Cable w/straps - 1/4”

Cable w/membrane - 1/2”


Waterproof Membrane

YES

YES

YES


Self-Leveling Concrete over Membrane

Yes, only approved brands

NO

Unknown


Modified Thin-set Approved Above and Below Membrane

Only Schluter thin-sets are approved over membrane to obtain the warranty

Yes, refer to thin-set & tile manufacturer


Minimum Tile Size Over Membrane

No minimum with use of self-leveler; 2”x2” over thin-set

2”x2” over thin-set

2”x2” over thin-set


UL Approved under Laminate

YES

YES

YES


UL Approved under Luxury Vinyl Tile

YES

YES

YES


UL Approved under Engineered Hardwood

YES

YES

YES


Membrane - Robinson Floor Test - OSB - 19.2” O.C - 12”x12” Porcelain

5/5 - Extra Heavy

DITRA-HEAT - 5/5 - Extra Heavy

DITRA-HEAT-DUO - 2/5 - Light

(16” O.C) - 2/5 - Light


Membrane - Robinson Floor Test - OSB - 24” O.C - 12”x12” Marble

 

DITRA-HEAT - 2/5 - Light

DITRA-HEAT-DUO - Unknown

 

Membrane - Robinson Floor Test - Concrete - 12”x12” Porcelain

5/5 - Extra Heavy

DITRA-HEAT - 3/5 - Moderate

DITRA-HEAT-DUO - 2/5 - Light


Membrane - Robinson Floor Test - Concrete - 2”x2” Porcelain

 

DITRA-HEAT - 2/5 - Light

DITRA-HEAT-DUO - 1/5 - Residential

 

Membrane - Robinson Floor Test - Concrete - 12”x12” Marble

 

DITRA-HEAT - Unknown

DITRA-HEAT-DUO - 2/5 - Light

 

Membrane Approved for Sound Reduction

NO

DITRA-HEAT - NO

DITRA-HEAT-DUO - YES

NO


Is the Membrane a Thermal Break?

NO

DITRA-HEAT - NO

DITRA-HEAT-DUO - YES, floor warmed 80% faster

NO


Cable Warranted in Other Membranes

YES

NO

YES


Membrane Warranted with Other Cable

YES

NO

YES, 5 years


Warranty in Effect After Repairs

YES

NO

YES, must get authorization first




helpful Videos


Downloads